Supplier Details
Add to My Basket
You can manage your basket in member center
Model No. | Connection Size | MWCO (Dalton) | Precision (μm) | Flux (L/·h) | Membrane Area () | Operation pressure (MPa) | Engineering (T/H) |
AQU-250A | DN50 | 100K | 0.01 | 40~100 | 32.7 | <0.2 | 10-150 |
AQU-250B | DN50 | 100K | 0.01 | 40~100 | 43.1 | <0.2 | 30-200 |
AQU-250C | DN50 | 100K | 0.01 | 40~100 | 54.3 | <0.2 | Above 100 |
Parameters | Units | Design Reference | Limit |
TSS | mg/L | <30 | 50 |
Turbidity | NTU | <10 | 15 |
Particle of Feed Water | µm | <50 | 100 |
Oil & Grease | mg/L | 0 | <5 |
PH Range, Continuous Operation | 6-9 | 2-12 | |
PH Range, Short-Term Cleaning | 2-12 | 2-12 | |
Operating Temperature | ºC | 25 | Lowest Temp. : 5ºC, Highest Temp : 45ºC |
Operating Pressure | MPa | 0.06~0.2 | 0.3 |
TMP. | MPa | <0.1 | 0.2 |
Chlorine Tolerance, Continuous Operation | mg/L | 50 | 100 |
Chlorine Tolerance, Short-Term Cleaning | mg/L | 100 | 200 |