LiFePO4 battery 24V 600ah standby battery
Replace SLA battery
Size is 704*320*310mm
Weight is 200KG
Use in electric richshaw vehicle, electric skatingboard, e-bike, e-motorcycle, e-car, solar light, UPS, electric boat, LED
Rated voltage 25.6V
Cut-off voltage 20V
Max charge voltage 29.2V
Max constant discharge rate ≤ 1C
Max instant discharge rate ≤ 1.5C
Max charge rate ≤ 1C, better 0.5C
Cycle 2000 times with 0.2C-1C discharge current
With balance BMS and charger.
1/3 weight of SLA battery
UL, CE, RoHS approved;
Supply ability: 3000pks/day
Package: 1pks/CTN
BMS--- battery management system solution
1. Battery management System prameter
Working voltage: 24V
Safety protection: Have insulation and leakage monitoring
Battery cell voltage, current detection: 0.5%, 20ms(sampling precision and time interval)
Battery usage record information: Voltage, current, temperature, SOC, SOH, insulation resistance.
Environment temperature: -20~55° C
Emergency treatment: Break the scramed switch or equip related Air Circuit Breaker
Temperature protection: 65° C(can be set)
Fan start temperature: 45° C
Overcurrent protection: 600 A(can be set)
Over charging protection: 3.90V(cell, can be set)
Over discharging protection: 2.5V(cell, can be set)
SOC estimation: 5%
SOH estimationequ: 5%
Max Equalization manage current: 1000mA(according to applied demand to equip)
Failure diagnosis: Over charging, Over discharging, short circuit, overheat, SOC over low or over high, insulation, low resistance; When overrun, disconnect affiliate relay by the superior commands, after exceeding the time limit, BMS disconnect the main relay actively
The definition of the whole commucation and connector: CAN2.0B; Accord with SAE1939
BMS is short for battery management system
1), battery cell voltage detection: Detect 0~12 piece(can be setted)cell voltage detection of the battery in series, cell voltage sampling range 0~4.5V, sampling precision± (0.3%RD+0.2%FS).
Total current: Current sampling range: -1000A~1000A, sampling precision± 1% not below national standard. Static state show 0, when sampling current is less than 0.5% full scale of Hall sensor, directly set up as 0, prevent zero-drift effection.
2), environment temperature:
Each collection module has 3temperature measuring transducer todetect environmental temperature, temperature sampling range -40° C~ 80° C, sampling precision ± 0.1° C.
3), battery equilibrium:
In use, choose active equilibrium, receive the Equilibrium command send by cotroller, can charge some relative battery cell, max equalizing current is 5A, close the equilibrium when not receive controller equilibrium command for more than 10s.
4), heat management driving interface:
Dry point output, can receive Heating device start temperature and stop temperature send by control modules, and Control heating management start and Stop according actual detect temperature, default is 15° When start, 25° Stop.
5), air fan management interface:
24V power supply output. Can receive air fan device start temperature and stop temperature send by control modules, and Control air fan management start and Stop according actual detect temperature, default is 45° Cwhen start, 30° C stop.
6), Communication interface: Offer CAN bus interface, uploading above 1 part and 2 partand 3 part collection information, and receive the control information of control module through CAN interface.
7), polling period: Cell detection period and module polling period not more than 10ms.
Standard capacity(0.2C) |
600ah |
Weight |
200kg |
Rated voltage |
24V |
Max. Charge voltage |
29.2V |
Cut-off voltage |
20V |
Standard charge and discharge current |
0.2C |
charging Time |
1-5hours |
Max discharge current |
1C |