- Gas Source: Biogas
Supplier Details
Add to My Basket You can manage your basket in member center
Spark Ignitiion Engine | Compression Ignition Engine | Gas Turbine | Combined Cycle | Back Pressure Steam Turbine | Pass Out Steam Turbine | |
Fuel Type | Natural gas, Biogas... | Natural gas, Biogas, Gas oil, Heavy oils | Natural Gas, Biogas, Gas Oil | Natural Gas, Biogas, Gas Oil | All types | All types |
Capacity Range | 30 kWe to 2 MWe | 100 kWe to 20 MWe | > 1 MWe | > 3 MWe | > 500 kWe | > 1MWe |
Heat: Power Ratio | 1: 1 to 3: 1 | 0.5: 1 to 1.5: 1 (3: 1 with boost firing) | 1.5: 1 to 2.5: 1 (5: 1 with supplementary firing) | 1: 1 (3: 1 with supplementary firing) | 3: 1 to 10: 1 | 3: 1 to 8: 1 |
Heat Output Quality | LPHW, Steam (rare) | LPHW, Steam | High Grade Steam | Medium Grade Steam | Medium Grade Steam | Steam at 2 pressures |
Electrical generating Efficiency % | 25-33 | 35-42 | 25-40 | 35-50 | 7-20 | 10-20 |
Overall Efficiency % | 70-78 | 65-75 (75-82 with boost firing) | 65-80 (75-82 with suppl. firing) | 73-80 (80-85 with suppl. firing) | 75-84 | 75-84 |