Supplier Details
Add to My Basket You can manage your basket in member center
MODEL | SSP3115C 1-12KW | |||||||||
1000W | 1500W | 2000W | 3000W | 4000W | 5000W | 6000W | 8000W | 10000W | 12000W | |
Input Wave form | Sine wave (utility or generator) | |||||||||
Nominal Voltage | 120VAC(option) 230VAC | |||||||||
Low voltage re trip | 90v ±4% & 184v/154v ±4% | |||||||||
Low voltage re engage | 100v ±4% & 194v/164v±4% | |||||||||
High voltage re trip | 140v ±4% & 253v ±4% | |||||||||
High voltage re engage | 135v ±4% & 243v ±4% | |||||||||
Nominal Input Frequency | 50Hz/ 60Hz (auto detection) | |||||||||
Low freq trip | 47Hz for 50Hz,57Hz for 60Hz High freq trip | |||||||||
High freq trip | 55Hz for 50Hz,65Hz for 60Hz | |||||||||
Output Wave form | (Bypass mode)same as input | |||||||||
Over-Load Protection | Circuit breaker | |||||||||
Short circuit Protection | Circuit breaker | |||||||||
Efficiency on line transfer mode | 95%+ | |||||||||
Line transfer time | 10ms Typical | |||||||||
Bypass without battery connected | Yes | |||||||||
Inverter specification/output | ||||||||||
Output wave form | Pure sine wave | |||||||||
Output continuos power watts | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 |
Output continuos power VA | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 |
Power factor | 0.9-1.0 | |||||||||
Nominal Output Voltage rms | 120VAC(option) 230VAC | |||||||||
Output Voltage regulation | +/- 10%rms | |||||||||
Output frequency | 50Hz ± 0.3Hz or 60Hz ± 0.3Hz | |||||||||
Safety Certification | >88% | |||||||||
Short circuit protection | Yes,fault after 1 secs | |||||||||
Inverter specification/input | ||||||||||
Nominal input voltage | 12V/24V/48V | 96V | ||||||||
Minimum start voltage | 10V/20V/40V | 80V | ||||||||
Low battery alarm | 10.5V/21V/42V | 84V | ||||||||
Low battery trip | 10V/20V/40V | 80V | ||||||||
High voltage alarm | 16V/32V/64V | 128V | ||||||||
Charger mode spe cification | ||||||||||
Output voltage | Dependent on battery type | |||||||||
Charge current | 10-85A MAX | 75A MAX | 85A MAX | 100A MAX | ||||||
Battery initial voltage for start up | 0-15.7v for 12v(*2 for 24v;*4 for 48v) | |||||||||
Over charge protection | 15.7v for 12v(*2 for 24v;*4 for 48v) | |||||||||
Solar Charger | ||||||||||
MPPT Range @ Operating Voltage | 15VDC~150VDC / 25VDC~150VDC / 60VDC~150VDC | 100~300VDC | ||||||||
maximum PV Array Open Circuit Voltage | 150VDC | 300VDC | ||||||||
Maximum Charging Current | 40A/60A | |||||||||
Macimum Effciency | >96% | |||||||||
Standby Power Comsumption | 2W |